The submarine optical cable is laid on the seabed with a wire bundle wrapped in an insulating sheath. The sea water can prevent the interference of external optical and magnetic waves, so the signal-to-noise ratio of the submarine cable is high; the time delay is not felt in the submarine optical cable communication; the design life of the submarine optical cable is continuous Worked for 25 years.
The basic structure of the submarine optical cable is: polyethylene layer, polyester resin or asphalt layer, steel strand layer, aluminum waterproof layer, polycarbonate layer, copper or aluminum tube, paraffin, alkane layer, optical fiber bundle, etc.
The submarine optical cable system is mainly used to connect optical cables and the Internet. It is divided into two parts: onshore equipment and underwater equipment. The onshore equipment packs and transmits communication services such as voice, image, and data.
Conception des câbles
| Objet | Caractéristiques physiques | Unité | Valeur nominale |
| Structure& Paramètre | Fibre | No. | 24/48/95/144/288 |
| FIMTO.D. | mm | 02.7 | |
| O.D. | mm | 13.6 | |
| Cable O.D. | mm | 031.7 | |
| Poids dans l’air, approximativement. | kg/m | 02.7 | |
| Poids en eau de mer, approximativement. | kg/m | 01.9 | |
| Objet | Caractéristiques physiques | Unité | Valeur nominale |
| Nominal | Profondeur océanique maximale de déploiement | m | 600 |
Spécification
| Pression hydrostatique | MPa | 6 |
| Charge minimale de freinage (UTS) | kN | 340 |
| Charge de traction transitoire nominale (NTTS) | kN | 240 |
| Charge de traction opérationnelle nominale (NOTS) | kN | 160 |
| Charge de traction permanente nominale, NPTS | kN | 120 |
| Rayon de courbure minimum. (vNPTS) | m | 1.0 |
| Rayon de courbure minimum. (>NPTS) | m | 1.5 |
| Plage de température de fonctionnement | °C | -10~+40 |
| Plage de température de manipulation | °C | -15~+45 |
| Plage de température de stockage | °C | -30-+60 |
| Tension de fonctionnement | kV | 0.5 |
| Tension de résistance DC | – | 15kV, 5min |
| Écrasement (IEC-794-1-E3) | kN | 40 |
| Impact (IEG794-1-E4) | J | 300 |
| Résistance du câble en courant continu | Q/km | < 2.0 |
| Résistance à l’isolation, conducteur d’eau/blindage | GQ.km | >10 |
| Gaine diamètre | μm | 125 | 1.0 |
| Gaine Erreur de concentricité du noyau | μm | ≤1 | – |
| Gaine Non-circularité | % | ≤2 | – |
| Diamètre du revêtement (non coloré) | μm | 245 | 10 |
| Erreur de concentricité de gaine | μm | ≤12 | – |
| Diamètre du champ de mode, MFD @ 1310 nm | μm | 9.2 | 0.4 |
| Atténuation @ 1310 nm | dB/km | ≤0.36 | – |
| Atténuation @ 1550 nm | dB/km | ≤0.22 | – |
| Longueur d’onde à dispersion nulle | nm | 1300-1324 | – |
| Pente de dispersion nulle | ps/nm2 •km | ≤0.092 | – |
| Dispersion chromatique @ 1310 nm | ps/nm • km | ≤3.5 | – |
| Dispersion chromatique @ 1550 nm | ps/nm • km | ≤18 | – |
| Dispersion des modes de polarisation, PMD | PS/VLCM | ≤ 0.2 | – |
| Longueur d’onde de coupure du câble | nm | ≤1260 | – |
| Niveau de test de démonstration | KPSI | >100 |
Références
| Doc ID | Titre du document |
| ISO 9001 | Systèmes de gestion de la qualité – Exigences |
| ISO 14001 | Systèmes de gestion environnementale |
| ITU-T G.652 | Caractéristiques d’une fibre optique et d’un câble monomode |
| ITU-T G.654 | Caractéristiques d’une fibre optique monomode à décalage coupé et d’un câble |
| IEC 60793-1 | Fibre optique Partie 1 : Spécifications génériques |
| IEC 60793-2 | Fibre optique Partie 2 : Spécifications du produit |
| IEC 60794-1-2 | Spécification générique – Procédures de test de base des câbles optiques |
| ITU-T G.976 | Méthodes d’essai applicables aux systèmes de câbles sous-marins à fibre optique |