The submarine optical cable is laid on the seabed with a wire bundle wrapped in an insulating sheath. The sea water can prevent the interference of external optical and magnetic waves, so the signal-to-noise ratio of the submarine cable is high; the time delay is not felt in the submarine optical cable communication; the design life of the submarine optical cable is continuous Worked for 25 years.
The basic structure of the submarine optical cable is: polyethylene layer, polyester resin or asphalt layer, steel strand layer, aluminum waterproof layer, polycarbonate layer, copper or aluminum tube, paraffin, alkane layer, optical fiber bundle, etc.
The submarine optical cable system is mainly used to connect optical cables and the Internet. It is divided into two parts: onshore equipment and underwater equipment. The onshore equipment packs and transmits communication services such as voice, image, and data.
Diseño de cables
| Punto | Características físicas | Unidad | Valor nominal |
| Estructura&Parámetro | Fibra | No. | 24/48/95/144/288 |
| FIMTO.D. | mm | 02.7 | |
| O.D. | mm | 13.6 | |
| Cable O.D. | mm | 031.7 | |
| Peso en el aire, aproximadamente. | kg/m | 02.7 | |
| Peso en agua de mar, aproximadamente. | kg/m | 01.9 | |
| Punto | Características físicas | Unidad | Valor nominal |
| Nominal | Profundidad oceánica máxima de despliegue | m | 600 |
Especificaciones
| Presión hidrostática | MPa | 6 |
| Carga mínima de frenado (UTS) | kN | 340 |
| Carga Térmica Nominal de Tracción (NTTS) | kN | 240 |
| Carga de Tracción Operativa Nominal (NOTS) | kN | 160 |
| Carga Permanente Nominal de Tracción, NPTS | kN | 120 |
| Radio mínimo de flexión. (vNPTS) | m | 1.0 |
| Radio mínimo de flexión. (>NPTS) | m | 1.5 |
| Rango de temperatura de funcionamiento | °C | -10~+40 |
| Rango de temperatura de manipulación | °C | -15~+45 |
| Rango de temperatura de almacenamiento | °C | -30-+60 |
| Voltaje de funcionamiento | kV | 0.5 |
| Tensión de soporte en CC | – | 15kV, 5min |
| Aplastamiento (IEC-794-1-E3) | kN | 40 |
| Impacto (IEG794-1-E4) | J | 300 |
| Resistencia de cable DC | Q/km | < 2.0 |
| Resistencia al aislamiento, conductor de agua/blindaje | GQ.km | >10 |
| Revestimiento Diámetro | μm | 125 | 1.0 |
| Error de concentricidad de revestimiento en núcleos | μm | ≤1 | – |
| Revestimiento No circularidad | % | ≤2 | – |
| Diámetro del recubrimiento (sin colorear) | μm | 245 | 10 |
| Error de concentricidad por revestimiento | μm | ≤12 | – |
| Diámetro del campo de modos, MFD @ 1310 nm | μm | 9.2 | 0.4 |
| Atenuación @ 1310 nm | dB/km | ≤0.36 | – |
| Atenuación @ 1550 nm | dB/km | ≤0.22 | – |
| Longitud de onda de dispersión cero | nm | 1300-1324 | – |
| Pendiente de dispersión cero | ps/nm2 •km | ≤0.092 | – |
| Dispersión cromática @ 1310 nm | ps/nm • km | ≤3.5 | – |
| Dispersión cromática @ 1550 nm | ps/nm • km | ≤18 | – |
| Dispersión de modos de polarización, PMD | PS/VLC | ≤ 0.2 | – |
| Longitud de onda de corte del cable | nm | ≤1260 | – |
| Nivel de prueba de demostración | KPSI | >100 |
Referencias
| Doc ID | Título del documento |
| ISO 9001 | Sistemas de Gestión de la Calidad – Requisitos |
| ISO 14001 | Sistemas de gestión ambiental |
| ITU-T G.652 | Características de una fibra óptica y cable monomodo |
| ITU-T G.654 | Características de una fibra óptica y cable monomodo con desplazamiento de corte |
| IEC 60793-1 | Fibra óptica Parte 1: Especificaciones genéricas |
| IEC 60793-2 | Fibra óptica Parte 2: Especificaciones del producto |
| IEC 60794-1-2 | Especificación genérica – Procedimientos básicos de prueba de cables ópticos |
| ITU-T G.976 | Métodos de prueba aplicables a sistemas de cables submarinos de fibra óptica |